Isolite E3MAC-2P

2200 — 12,500 VA

Single Phase Modular AC Inverter

Isolite E3MAC-2P

2200 — 12,500 VA

The Isolite E3MAC2P is a 2,200 – 12,500 VA two-phase modular AC inverter. It has a programable and password-protected user interface allowing for optional web monitoring. It is 98% effective for minimal BTU losses and has a PWM Inverter that provides pure sine wave output with less than 3% THD. For better load and site compatibility, a programmable transfer time can be changed between standard and fast transfer times.


The crest factor has >4 overload protection for demanding high in-rush loads. The UL is listed for a 90-minute run-time and is compatible with all light loads, including HID. The inverter battery recharges in less than 24 hours and has a variable time delay, two-phase output, and a startup diagnostic to confirm proper installation.

Standard Features

  • Features

    • Optional Web-based Monitoring Platform – easily view, interact with, download
    • and manage records as needed on any PC or mobile device
    • Programmable and password protected user interface
    • 98% efficient for minimal BTU losses
    • PWM Inverter provides pure sine wave output with less than 3% THD
    • Crest factor >4 overload protection for demanding high in-rush loads
    • Programmable transfer time – select between standard and fast transfer times
    • for load and site compatibility
    • UL listed 90 minute run-time
    • Compatible with all lighting loads, including HID
    • Variable time delay
    • Battery recharges in less than 24 hours
    • Two Phase output
    • Start-Up Diagnostics checks for proper installation

Power Rating: 2200-12,500 VA

Voltage: 120V, 120V/208V, 277V, 277V/480V

Product Series: E3MAC

Battery

Front access VRLA batteries with 10-Year pro-rated warranty


Temperature Rating

From 68°F to 86°F


Environment

Operating Temp: 20C° to 30C° (68ºF to 86ºF)

Storage Temp: Electronics - 20C° to 70C° (68ºF to 158ºF)

Relative Humidity: <95 % (non-condensing)


Safety Standards

UL 924, OSHPD Seismic Certified (with Z4 option), New York City Approved, Calendar Number 51575, NFPA 101 Life Safety Code, NFPA 70-NEC, OSHA, NEMA Type 1 enclosure

Download our brochure to learn more.

Related Products

Can't find what you are looking for? We're here to help. Chat with a representative instantly or call 888.501.1887.

ABB — IPS "Interruptible"

1.5 kVA — 16.7 kVA

View Product

ABB — FTC "Fast Transfer System"

1.5 kVA — 16.7 kVA

View Product

ABB Compact

500 VA — 2000 VA

View Product

ABB Mini Inverter Series

125 W, 250 W, 400 W, or 720 W

View Product

ABB High Capacity Mini Inverter

1000W

View Product

DSPM Eternalight Mini

350 W — 2000 W

View Prodct

DSPM Eternalight Micro

75 W — 375 W

View Product

DSPM Eternalight 1 Outdoor

75 W — 21 kW

View Product

DSPM Eternalight 1 Harsh

75 W — 21 kW

View Product

DSPM Eternalight 1

4.7 kW — 21 kW

View Product

DSPM Eternalight Plus

2.4 kW — 4.2 kW

View Product

EATON 9155 UPS

8 — 15 kVA

View Product

STACO UniStar SCLI 924

350 W — 21.0 kW

View Product

Lighting Inverter Enclosures

120 V — 480 V

View Product

Harsh Environment UPS

3 kW — 17 kW

View Product

Micro Power Wave

200 W — 490 kW

View Product

Mini Power Wave

500 W — 2700 kW

View Product

Nano Wave

27 W, 36 W, 200 W

View Product

Power Wave 1

2.1 kW — 17 kW

View Product

Shaker Table Power Wave 1

2.1 kW — 17 kW

View Product

Isolite E3

300 — 550 VA

View Product

Isolite E3MAC-1P

1000 —12500 VA

View Product

Isolite E3MAC-2P

2200 — 12500 VA

View Product

Isolite E3MAC-SP

2200 — 12500 VA

View Product

Isolite MPS

20 — 55 Watts

View Product

ABB — IPS "Interruptible"

1.5 kVA — 16.7 kVA

View Product

ABB — FTC "Fast Transfer System"

1.5 kVA — 16.7 kVA

View Product
View All

Single Source Lighting Inverter Provider

Expert assistance from Technical Consultants assist in the selection process of your next Inverter System. Our team is available for Technical Review of specifications, Sizing assistance, Voltage selection, and Runtime Calculations.

Latest News

Stay up-to-date with Lighting Inverter's news and resources about the industry!

Our Resources
a red exit sign is hanging from the ceiling in a dark room .
27 Feb, 2024
Illuminate the path to safety with our guide on emergency lighting code compliance. Ensure your spaces meet safety standards effectively.
By Tyler Marks 31 Jan, 2024
Electrical supplies for homes and businesses commonly use single-phase alternating current (AC). This alternating current works with most appliances, simple office equipment, lighting, and other devices. Yet for large companies with complex equipment and in many other countries, equipment relies on three-phase alternating current. There are some key differences, advantages, and disadvantages when comparing single-phase vs three-phase power. Understanding these differences will allow you to select the right one for your company.
13 Oct, 2023
A lighting inverter system is made up of it’s power conditioning component, inverter components, charging, and the backup runtime component which are batteries. The UL 924 compliance code requires that 90 minutes of battery minimum are provided to all exit sign routes. This 90 minute runtime can only pass it’s minimum test by having well charged, healthy batteries.

Request a Quote


Experienced Product Representatives are on hand to send you information and quotations for equipment. If you need help with sizing, installation planning, or general questions about product please fill in the appropriate form and someone will contact you shortly. You may also call 844-501-1887 to get a direct product representative.

Eaton 9355 UPS Page Form