eternalight 3 harsh

Eternalight 3

Defends your environment against unwanted power outage and electrical disturbances by providing:

  • DSPM Watchdog software always on guard.
  • Display monitor keeps you in control 24/7.
  • Dependable DSP/PWM technology for unsurpassed reliability.
  • Economical for the lowest overall cost to your light safety with an Energy Star Rating.
  • Temperature compensation technology that controls batteries for the longest battery life.
  • Sealed maintenance-free batteries.
  • Full light output for an entire 90 minutes.
  • Self-diagnostics for a safe and secure lighted environment.
  • Pure sine wave output for all types of lamps.
  • ECM module is a patented technology used by DSPM.
  • Backup solutions for multiple applications such as
    • Indoor and outdoor emergency lighting
    • Exits
    • Cash registers
    • Computers
    • Strategic electronics
    • And more
  • 10 Year pro-rated battery warranty.
  • 5 Year power train warranty.
  • Listed to UL924, UL1778. and UL508.
  • Cities of Chicago and New York approved.
  • Complies with the Buy American Act.

Contact Us about DSPM Eternalight 3 Harsh

    Product Snapshot
    Standard Power Levels (KW)0.075, 0.1, 0.125, 0.2, 0.3, 0.35, 0.525, 0.7, 0.875, 1.05, 1.4, 2.0, 2.4, 2.6, 3.0, 3.4, 3.8, 4.2, 4.7, 5.25, 7.0, 8.0, 10.0, 12.0, 14.0, 18.0, 21.0
    Crest Factor2:5:1 typical
    Surge Protectionthe unit will protect itself and the load against surges as defined in ANSI/IEEE C62.45 Category A and B
    Technical Specs
    Efficiency≥92% at 100% linear road
    Audible Noise<45dB measured on Response Curve “A”
    ETL ListedUL924 and UL1778
    Operating Temperature-20° to 50° Celsius (-4° to 122°F)
    Storage Temperature-20° to 60° Celsius (-4° to 140°F)
    Humidity5 – 100%; Non-condensing
    CabinetNEMA-4

    Input:

    Input Voltage120, 208, 240, 277, or 480 VAC
    Input Voltage Range+10% -15%
    Input ProtectionInput Main Circuit Breaker

    Output:

    Output Voltage120, 277, 480, 120/240 or 120/277 VAC
    Output Voltage Regulation±3% for all loads and battery discharge mode
    Output Frequency Range60 Hz, ±1%
    Output Wave FormSine-wave <5% @ 100% linear load
    Output ProtectionOutput Main Circuit Breaker

    Battery:

    BatterySealed maintenance-free (AGM) lead calcium
    Recharge CurrentConforms to UL924 standards
    External BatteryProvision for hardware connection of external battery
    cabinets or DC source

    PDFS
    Eternalight 3 Harsh Cabinet Conduit DrawingEternalight 3 Harsh Cabinet Conduit Drawing.pdf
    Eternalight 3 Harsh Cabinet Placement DrawingEternalight 3 Harsh Cabinet Placement Drawing.pdf
    Eternalight 3 Harsh Integration Drawing 3-10kWEternalight 3 Harsh Integration Drawing 3-10kW.pdf
    Eternalight 3 Harsh Integration Drawing 12-30kWEternalight 3 Harsh Integration Drawing 12-30kW.pdf
    Eternalight 3 Harsh Integration Drawing 40-125kWEternalight 3 Harsh Integration Drawing 40-125kW.pdf
    Eternalight 3 Harsh System Current RatingsEternalight 3 Harsh System Current Ratings.pdf
    Eternalight 3 Harsh Lighting Inverter BrochureEternalight 3 Harsh Lighting Inverter Brochure.pdf
    DSPM Harsh 3 Outdoor Data SheetDSPM Harsh 3 Outdoor Data Sheet.pdf
    DSPM Inc Eternalight 3 Harsh Technical SpecificationsDSPM Inc Eternalight 3 Harsh Technical Specifications.pdf
    Eternalight 3 Harsh 208V Maintenance ManualEternalight 3 Harsh 208V Maintenance Manual.pdf
    Eternalight 3 Harsh 208V User’s ManualEternalight 3 Harsh 208V User’s Manual.pdf
    Eternalight 3 Harsh 480V Maintenance ManualEternalight 3 Harsh 480V Maintenance Manual.pdf
    Eternalight 3 Harsh 480V User’s ManualEternalight 3 Harsh 480V User’s Manual.pdf