• Eaton 93pm UPS
  • Eaton 93pm UPS
  • Eaton 93pm UPS
  • 93PM model
  • 93pm model
  • 93pm model
  • 93pm model
  • Eaton 93pm UPS
  • Eaton 93pm UPS

Eaton 93PM UPS

The EATON 93PM UPS combines unprecedented efficiency, reliability, and vertical or horizontal scalability with eye-catching design. A space-saving, flexible device that’s as easy to deploy as it is to manage, it’s the perfect UL 924 approved system for central inverter applications.

Contact Us about Eaton 93PM UPS

    Features & Benefits

    • Reduces power and cooling OPEX through industry-leading energy efficiency.
    • Conserves valuable data center floor space with its compact footprint and internal redundancy design.
    • Reduces cost and unexpected future growth risks with it’s vertical scalability, enabling you to scale as you grow.
    • Maximizes deployment flexibility by providing innovative thermal management options, flexible configurability and full-service access from the front.
    • Simplifies installation by fitting perfectly in line or alongside any standard-depth rack
    • Provides easier access to detailed status information through its large, user-friendly LCD touchscreen interface
    • Optimizes server virtualization solutions through its full suite of power management and connectivity software.
    • Increases uptime through its 24×7 remote monitoring and reporting capabilities.
    • VRLA and Lithium-ion Battery Systems available. Ask your representative.
    Product Snapshot
    Power Rating50, 50+1, 100, 100+1, 150, 150+1, 200 kVA
    Voltage480V (208 with IAC-D)
    Frequency50/60Hz
    EfficiencyUp to 97% in double conversion
    99% in Energy Saver System
    ScalabilityInternal up to 4
    External up to 8
    ConfigurationTower
    BatteriesInternal batteries up to 50 kW; external batteries up to 200 kW
    Technical Specs

    Power Modules:

    Power Offering (kW)50, 50+1, 100, 100+1, 150, 150+1, 200**
    (Derates available in 10 kW increments)

    General Characteristics:

    Efficiency in Energy Saver Systems (ESS)99%
    Efficiency in Double-Conversion ModeUp to 97%
    Parallel Capability8 distributed

    Imput Characteristics:

    Voltage480V (208V with IAC-D)
    Voltage Range +10% / -15%
    Frequency Range 50/60 Hz
    Power Factor >.99
    Input Current Distortion <3% @ 100% load capacity

    Output:

    Voltage480V (208V with IAC-D)
    Regulation ±1% steady state
    Voltage THD<1% (100% linear load); <5% (non-linear load)
    Load Power Factor Range.8 leading to .8 lagging without de-rating

    Battery:

    Battery Voltage 432V VRLA or Lithium Ion
    Charging MethodABM® or float technology

    Certification:

    SafetyUL1778, cUL
    EMCFCC Part 15 subpart B class A
    Surge IEC 61000-4-5

    Optional Accessories:

    External slim maintenance bypass
    Integrated distribution cabinet (with input and output transformer options)
    Integrated parallel tie cabinets
    Integrated battery cabinet (small and large)

    1. Due to continuous product improvements, program specifications are subject to change without notice.

    PDFS
    Eaton 93PM UPS BrochureEaton-93PM-UPS-Brochure.pdf
    Eaton 93PM UPS Technical SpecsEaton-93PM-UPS-Technical-Specs.pdf